The JA-80Z signal repeater can extend the range of remote devices whose signal is not strong enough to communicate with the control panel or whose communication is unreliable. .
The repeater function lies in the retransmission of a signal received from an enrolled device with a little delay. The delay ensures that a possible conflict between the repeater transmission and the transmitting device is avoided. Each device enrolled to the repeater must concurrently be enrolled to the control panel A double-balanced INP input with a selectable natural reaction (default: delayed loop) is available for the connection of one hard-wire detector. Activation of this input is transmitted to the control panel as a signal from a device to which the repeater has been enrolled in the control panel. The reaction of this loop can be configured in the control panel. The repeater front cover is protected with a built-in tamper sensor and the box must be protected against being torn off the wall with a tamper device delivered with the package. The repeater must be equipped with a backup battery (e.g. SA-214/1,3) which ensures its operation when there is a power supply failure.
Specifications
Power source
230 V / 50 Hz, max 0.1 A, protection class II
Power supply
type A (EN 50131-6)
Backup battery
12 V, 2.2 Ah
Backup power output
maximum continuous load 0.7 A
Number of wireless device addresses
40
Hard-wired inputs
1x double balanced input (one input reserved for the rear tamper contact)
EW external warning output
switching to GND, max. 0.5A
IW internal warning output
switching to GND, max. 0.5A
PGX, PGY outputs
max. 0.1 A, switching to GND
Frequency (JA-82R)
868 MHz
Security grade
2 (according to EN50131-1, EN 50131-6 and EN 50131-5-3)
Environmental class
II. indoor-general (-10 to +40°C) compliant with EN 50131-1
Radio emissions
ETSI EN 300220
EMC
EN 50130-4, EN 55022
Safety
EN 60950-1
Can be operated according to
ERC REC 70-03
Manual in PDF : Click Here