The JA-63 "Profi" is a programmable modular control panel. Splitable into 2 sections (with a shared section). Built in power supply and ample space for a backup battery (12V, 1.3Ah or 2.6Ah).
The JA-63K main board has 4 hard-wired inputs with programmable triggering (NC, balanced or double balanced) and programmable reactions.
Model JA-63KR (equipped with the "R" radio communicating module) has 16 wireless zones. Up to two JA-60 detectors can enrolled into each zone (totally 32 as a maximum). In total model 63KR has 20 zones (4 wired and 16 wireless). Up to 8 wireless controllers (remote controls or wireless keypads), a JA-60A wireless siren and unlimited number of UC family wireless output modules can be enrolled as well. If more zones are required, another JA-6x control panel can be enrolled as a subsystem (Master & Slave architecture). The master control panel receives information from the sub control panel and it can also arm and disarm the subsystem panel.
Telephone module "X" can communicate with a Monitoring Station, send two voice messages, send five SMS messages via SMS server (or dial a numeric Pager) or. It can also communicate with a remote PC (using ComLink SW and a JA-60U modem).
Operation and programming is possible via the JA-60E keypad (either directly wired to the control panel or remotely using JA-60U modem). The control panel equipped with a radio module (63KR, 63KRX) can also be programmed and operated by a JA-60F wireless keypad and can also be operated by RC-11 or RC-22 remote controls or by a JA-60D wireless keypad. Operation and programming is also possible via a PC using ComLink SW (locally or remotely via JA-60U modem).
| Electrical | |
|---|---|
| Power | 230 VAC, max 0.1 A, supervised, class II |
| Backup battery | 12 V, from 1.3 or 2.6 Ah, normal life time 5 years |
| Backup power output | 13VDC, the max. permanent current is 0.4 or 1.2 A for max. 15 min (1 cycle per hour), self consumption of the control panel is 30mA |
| Hard-wired inputs | 4 input zones, selectable triggering: NC, EOL resistor or Double EOL resistor |
| Zone reactions | selectable: instant, delayed, panic, fire, 24 hour, next delayed |
| Wireless zones** | 16 zones (2 detectors can be enrolled to each = up to 32 detectors totally) |
| Frequency** | 433.92 MHz; digital hopping code; supervised communication |
| Keypads | max. 4 wired JA-60E keypads, max. 8 JA-60F wireless keypads** or RC-11 or JA-60D remote controllers ** |
| Access codes | master code and 14 user codes. When system is split, codes, detectors and remote controls can be addressed to particular sectors |
| Wired outputs | Alarm relay dry contacts 1A/60V; programmable outputs PgX & PgY (Chime, Fire, Arm, Panic, Alarm, Door, Home, AC failure), siren output (12 V, 0.7 A) |
| Wireless outputs** | control panel transmits signals for siren and PgX, PgY data for UC-2xx receivers |
| Events memory | 127 most recent events including date, time and detailed specification |
| Telephone communicator* | module 65X: digital communication to a monitoring station, 5 SMS messages or Pager dialing, 2 voice messages, modem communication with a remote PC (ComLink SW + JA-60U modem), remote keypad access with JA-60E and JA-60U |
| Monitoring station formats* | Contact ID, Ademco, Telemax, Franklin, Radionics, SurGard, DTMF2300, (198 reports codes) |
| * control panel equipped with telephone dialer JA-65X ** wireless control panel (JA-63KR, JA-63KRX) |
|
| Environmental | |
| Operating temperature | -10°C to 40° C |
| Operating humidity | max 80 % |
| Working environment | indoor use (class II, EN 50131-1) |
| Immunity | |
| Electrostatic discharge | 8 kV |
| RF immunity | 30 V / m |
| Physical | |
| Housing | plastic box with built-in power supply |
| Dimensions | see diagram bellow |
| Standards | |
| Complies with | EN 50131-1 (Grade 2), EN 50131-6, EN 300220, ETS 300 683, EN 501 |
User Manual in PDF: Click Here